Length | 600 | 1200 | 1500 | |||||||||||||
Existing equipment |
T5 |
T5 2x24W |
T8 2x18W |
T5 2x28W |
T8 2x36W |
T5 2x54W |
T5 3x54W |
T5 4x54W |
T5 2x49W |
T8 2x58W |
T5 2x80W |
T5 3x49W |
T8 3x58W |
T5 4x49W |
T5 3x80W |
T8 4x58W |
System power*/Luminaire lumen** | 31W 1686lm |
53W 2453lm |
47W 1890lm |
62W 3646lm |
94W 4687lm |
119W 6199lm |
178W 9299lm |
237,6W 12398,4lm |
108W 6037lm |
151W 7308lm |
176W 8624lm |
162W 9055lm |
226W 10962lm |
216W 12074lm |
264W 12936lm |
302W 14616lm |
Replacement from Hide-a-lite: |
||||||||||||||||
Liteline IP44 600 | 22W 2840lm |
22W 2840lm |
22W 2840lm |
|||||||||||||
Liteline Basic IP44 1200 | 38W 4630lm |
38W 4630lm |
||||||||||||||
Liteline IP44 1200 | 36W 4850lm 800mA |
36W 4850lm 800mA |
46W 6350lm 1050mA |
|||||||||||||
Liteline IP65 1200 (On/Off / Sensor) | 40W 5150lm 900mA |
40W 5150lm 900mA |
53W 6490lm 1200mA |
|||||||||||||
Liteline IP65 1200 (DALI / Bluetooth) | 38W 5150lm |
38W 5150lm |
||||||||||||||
Liteline IP65 1500 (On/Off / Sensor) | 50W 6850lm 1050mA |
59W 7800lm 1200mA |
||||||||||||||
Liteline IP65 1500 (DALI / Bluetooth) | 49,5W 6850lm**** |
49,5W 6850lm |
49,5W 6850lm*** |
|||||||||||||
Indline IP23 M Medium | 33W 5520lm 325mA |
33W 5520lm 325mA |
44W 7000lm 425mA |
|||||||||||||
Indline IP23 L Medium | 32W 5550lm 325mA |
32W 5550lm 325mA |
39W 6700lm 400mA |
58W 9650lm 600mA |
||||||||||||
Indline IP23 XL Medium | 81W 14000lm 500mA***** |
53W 9500lm 325mA |
53W 9500lm 325mA |
53W 9500lm 325mA |
53W 9500lm 325mA |
66W 11600lm 400mA |
81W 14000lm 500mA |
81W 14000lm 500mA |
||||||||
Indline IP23 XXL Medium | 84W 15500lm 325mA***** |
84W 15500lm 325mA |
84W 15500lm 325mA |
84W 15500lm 325mA |
Luminaire lumen & and power are stated for 4000K.
Note that the replacement beam angle and IP Degree of Protection should be equivalent to existing luminaires.
Columns with reference to mA refer to the product’s system power and luminaire lumen with the stated DIP-Switch Power. This is configured in the product’s driver.
* We report the luminaires’ system power with the standard markup below on the total power of the light sources to take drive losses into account:
T5: HF driver +10%
T8: Magnetic current limiter +50%
** We have assumed that the fluorescent tube luminaire has 70% efficiency when calculating luminaire lumen based on light source lumen.
*** Gives slightly less light
**** Replacement fixture is 1500mm
***** Replacement fixture is 1800mm
Using different control solutions you can save even more, depending on the type of space, how it is used and the circumstances of the project. We are happy to help with energy saving calculations and lighting calculations for replacement in your project.
The examples below are for a surface for 500lux. By changing from fluorescent tubes to LEDs, you can make energy savings of up to 70% depending on the lighting solution that you choose.
The examples below are for a warehouse aisle with 200lux. By changing from fluorescent tubes to LEDs, you can make energy savings of up to XX% depending on the lighting solution that you choose. In the calculations below for control, we have worked from reduction factors in “Ljus & Rum” section 6 with standard values for warehouse aisles.