The importance of light in sports facilities


The light plays an important part

In sports facilities the light has an important role - it shall meet the players’ needs, but at the same time not be a disturbance. As an aid for light planning and installation of sports lighting, the European standard EN 12193 is applicable. The standard describes, amongst others, that consideration should be given to glare, colour rendering and the illuminance in differing grid points, partly in the main area for the sport and partly in the peripheral area around the playing surface. The requirements for lighting are different depending on the sport concerned. There are three different classes for each sport based on if it is school sports, training and competition as well as local, regional or international.


Sports lighting that passes ball tests

When there is a requirement for the luminaire to be extra durable against ball impacts, it is tested according to VDE 0710-13, a so-called ball test. In order to pass the standard test the luminaire must withstand 36 shots from three different directions at 60 km/h with a calibrated handball with a diameter of 187 mm without any parts coming loose or that the IP classification is affected.

Our Indline Sport Grid IP23 with its different light alternatives is optimised to meet the requirements in a sports facility. Indline Sport Grid IP23 also has several different lens options that give a broad, medium or narrow beam, or an asymmetrical light. The asymmetrical light is ideal for padel courts, for example. Our sports luminaires also have a long life time, which implies a minimal amount of maintenance over time. Quite simply - a perfect sports luminaire.


To help you in your next project with sports lighting we have produced a number of calculations example


Calculation example, padel

+= grid points  
Reflection factors  50/30/20
Luminaires Indline Sport IP23 XL Asymmetric
E-no  7392971144009
Quantity  14
Mounting height   8m

 

   Emed[lx]  Emin/Emed
Horizontal illuminance (at floor level)  513  0.72

Calculation example, multi-purpose halls

+= grid points  
Reflection factors  50/30/20
Luminaires Indline Sport Grid IP23 XL Medium
E-no  7392971144146
Quantity  32
Mounting height   7m

 

   Emed[lx]  Emin/Emed
Horizontal illuminance (at floor level)  325  0.87

Our Indline Sport Grid IP23 with its various lighting alternatives is optimised to meet the requirements for a sports facility

OPTIMISED SPORTS LIGHTING

- For Bankeryd Padel Centre

Read the case here